Life safety does not live in Flows. It lives in firmware.
Flows is a control layer, not a safety layer. The loops that installation integrity or human safety depend on will not execute in Flows, nor even on the gateway: they will execute in the firmware of the module in the wall, on local dry inputs, with no network component in the loop.
The reference case is the wood-burning fireplace boiler. If the water goes over the threshold, the module will start the circulation pump and open the valve through its own local logic — even if the gateway is off, the local network is down and the internet is gone. The same category covers pulse commands for gates and the hardware mutex between the two directions of a blind: to be applied in firmware, not through rules.
The separation is correct precisely because Flows can be rewritten by the user. A layer that changes with two clicks cannot at the same time be the layer safety rests on. And where a standard requires a mechanical element — the thermal discharge valve on the fireplace boiler — it remains mandatory and is not part of Mentivira. We do not present Mentivira as a certified safety system.
CE conformity and the cybersecurity requirement of the Radio Equipment Directive (RED, Art. 3.3, through the EN 18031 standards) are conformity objectives we are working towards, with a security dossier in progress — not certifications already held. When we obtain them, we will show them.